*HEADING Import analysis: standard-explicit *IMPORT,UPDATE=NO,STATE=YES EALL, *RESTART, WRITE ** *AMPLITUDE, NAME=RAMP 0.0,0.0,1.0,1.0 *ELSET,ELSET=TIP,GEN 97,105,4 98,106,4 99,107,4 100,108,4 *ELSET,ELSET=QA_TEST TIP, *NSET,NSET=QA_TEST TIP, *STEP Apply torque to tip of beam *DYNAMIC, EXPLICIT ,0.01 *BOUNDARY,OP=NEW BUILTIN,1,3 *CLOAD, OP=NEW, AMPLITUDE=RAMP 50, 3, 0.75E7 100,3, 0.75E7 150,3, 0.75E7 200,3, 0.75E7 10, 3,-0.75E7 60, 3,-0.75E7 110,3,-0.75E7 160,3,-0.75E7 ********************** *OUTPUT,HISTORY,TIME INTERVAL=0.001 *ENERGY OUTPUT, VARIABLE=PRESELECT *OUTPUT, FIELD, NUMBER INTERVAL=5 *ELEMENT OUTPUT, VARIABLE=PRESELECT *NODE OUTPUT, VARIABLE=PRESELECT ******************** *FILE OUTPUT,NUMBER INTERVAL=1 *NODE FILE, NSET=TIP U, *EL FILE, ELSET=TIP LE, ******QA TEST******** *OUTPUT, FIELD,NUMBER INTERVAL=1 *NODE OUTPUT, NSET=QA_TEST U, *ELEMENT OUTPUT, ELSET=QA_TEST LE, *OUTPUT,HISTORY,TIME INTERVAL=0.01 *ENERGY OUTPUT, VARIABLE=PRESELECT *********************** *MONITOR, DOF=3, NODE=50 *END STEP