*HEADING
EXPLICIT CFILM AND CFLUX LOADS TEST [C3D6T]
*PREPRINT,ECHO=YES,HISTORY=NO,MODEL=NO
*NODE,NSET=ALL
1,0,0,0
2,1,0,0
3,1,1,0
4,0,1,0
5,0,0,2
6,1,0,2
7,1,1,2
8,0,1,2
*ELEMENT,TYPE=SC6RT, ELSET=EALL
1,1,2,3,5,6,7
2,3,4,1,7,8,5
*SHELL SECTION,MATERIAL=A1, ELSET=EALL
1.0
*MATERIAL,NAME=A1
*ELASTIC
1.0,0.0
*CONDUCTIVITY
1.0, 
*DENSITY
1.0, 
*SPECIFIC HEAT
1.0, 
*EXPANSION
0.0, 
*NODE,NSET=REFNODE
9999,0.5,0.5,1.0
*RIGID BODY,REF NODE=9999,ELSET=EALL,ISOTHERMAL=YES
*ELEMENT,TYPE=HEATCAP,ELSET=CAP
99001,9999
*HEATCAP,ELSET=CAP
1.0
*INITIAL CONDITIONS,TYPE=TEMPERATURE
9999,100
*NSET,NSET=QA_TEST_ALLNODES
ALL,REFNODE
*NSET,NSET=QA_TEST_QA_TEST_ALLNODES
QA_TEST_ALLNODES,
**
*STEP
 COOL DOWN BY CONVECTION
*DYNAMIC TEMPERATURE-DISPLACEMENT, EXPLICIT, DIRECT
0.5,10.0
*CFILM
9999,2.0,20,1.0
*FILE OUTPUT, NUM=1
*NODE FILE,NSET=QA_TEST_ALLNODES
 NT
*OUTPUT,FIELD,NUM=1
*NODE OUTPUT,NSET=QA_TEST_ALLNODES
 NT,
**
*OUTPUT, HISTORY,FREQ=2
*NODE OUTPUT, NSET=ALL
NT,
*NODE OUTPUT, NSET=REFNODE
NT,
*OUTPUT, HISTORY,TIME INTERVAL=10.0
*ENERGY OUTPUT,VAR=ALL
*OUTPUT, FIELD, NUMBER INTERVAL=1
*NODE OUTPUT, NSET=QA_TEST_QA_TEST_ALLNODES
 NT
*OUTPUT,HISTORY,VARIABLE=PRESELECT,TIMEINT=10
***OUTPUT,HISTORY,VARIABLE=PRESELECT
*ENDSTEP
*****************************************
*STEP
HEATED UP BY PRESCRIBED FLUX
*DYNAMIC TEMPERATURE-DISPLACEMENT, EXPLICIT, DIRECT
0.5,10.0
*CFILM,OP=NEW
9999,2.0,20,0.0
*CFLUX,OP=NEW
9999,11,24,1.0
*FILE OUTPUT, NUM=1
*NODE FILE,NSET=QA_TEST_ALLNODES
 NT
*OUTPUT, FIELD, NUMBER INTERVAL=1
*NODE OUTPUT, NSET=QA_TEST_QA_TEST_ALLNODES
 NT
*OUTPUT,HISTORY,VARIABLE=PRESELECT,TIMEINT=10
*ENDSTEP