*HEADING
NAFEMS TEST T3, 1-Dimensional Transient Heat Transfer  [CPS3T]
**
** The target solution is the temperature at NOUT nodes:T_nout=36.6, 
** at 32 sec. See ch. 1.11.6 of ABAQUS/Verification Manual
**
*PREPRINT,ECHO=YES,HISTORY=NO,MODEL=NO
*NODE
 1  ,0.0  , -0.005
 101,0.0  , -0.000
 201,0.0  ,  0.005
 41 ,0.1  , -0.005
 141,0.1  , -0.000
 241,0.1  ,  0.005
*NGEN,NSET=NALL
 1  , 41  ,4
 101, 141 ,2
 201, 241 ,4
*NSET,NSET=NOUT
33,233
*NSET,NSET=QA_TEST
NOUT,
*ELEMENT,TYPE=CPS3T
 1, 201,  1,  9
 2,   9,209,201
*ELGEN, ELSET=EALL
 1,5,8,2
 2,5,8,2
*MATERIAL,NAME=A1
*EXPANSION
0.0, 
*ELASTIC
1.,0.
*CONDUCTIVITY
35.0, 
*DENSITY
7200., 
*SPECIFIC HEAT
440.5, 
*BOUNDARY
  1,11,,0.
201,11,,0.
*SOLID SECTION,MATERIAL=A1, ELSET=EALL
*AMPLITUDE,NAME=SINE,DEFINITION=PERIODIC,VALUE=A
1,0.07854,0.0
0.0,100.0
*NODE,NSET=REFNODE
9999,0.,0.,0.
*RIGID BODY,ELSET=EALL,REFNODE=9999,ISOTHERMAL=NO
*STEP
*DYNAMIC TEMPERATURE-DISPLACEMENT,EXPLICIT
 ,32.,
*BOUNDARY,AMP=SINE
 41,11,,1.
241,11,,1.
**************************
*FILE OUTPUT,NUM=1
*NODE FILE,NSET=NOUT
NT,
**************************
*OUTPUT,FIELD,NUMBER INTERVAL=1
*NODE OUTPUT
NT,
*NODE OUTPUT,NSET=QA_TEST
NT 
***************************
***OUTPUT,HISTORY,FREQ=1
***NODE OUTPUT,NSET=NOUT
**NT,
********** 
*OUTPUT,HISTORY,TIME INTERVAL=32.0
*ENERGY OUTPUT,VARIABLE=ALL
****************************
*END STEP