*HEADING
Import analysis: standard-explicit
*IMPORT,UPDATE=NO,STATE=YES
EALL,
*RESTART, WRITE
**
*AMPLITUDE, NAME=RAMP, DEF=SMOOTH STEP
0.0,0.0,0.1,1.0
*STEP
Apply torque to tip of beam
*DYNAMIC, EXPLICIT
,0.1
*BULK VISCOSITY
0.006, 0.12
*BOUNDARY,OP=NEW
BUILTIN,1,6
*CLOAD, OP=NEW, AMPLITUDE=RAMP
50,3,0.75E5
10,3,-0.75E5
*OUTPUT, FIELD,NUMBER INTERVAL=1
*ELEMENT OUTPUT
S,LE
*NODE OUTPUT
U,
*OUTPUT, FIELD, NUMBER INTERVAL=2
*NODE OUTPUT,NSET=QA_TEST_TIP
COORD,UT
*MONITOR, DOF=3, NODE=50
*END STEP